N120 N120 21 CFR Significant Step Closer

Implen NanoPhotometer® N120

With 12 Samples per Run, it’s a Significant Step Closer to Automation

Implen-NanoPhotometer-N120-12-Samples-per-Run-Fully-Compliant-with-FDA-21-CFR-Part-11-LIMS-Integration-Ready-via-REST-API implen advantages Avoid Manual Errors
implen advantages Save Time
implen advantages Fully Compliant with FDA 21 CFR Part 11
implen advantages LIMS Integration Ready via REST API

Avoid manual errors and save time: With full scan capability range from 200 – 900 nm for rapid and complete sample analysis in as little as 1.7 seconds per sample, the NanoPhotometer® N120 record breaking design will exceed expectations. Measure 96 samples up to 126 times faster with 33% less operational steps required when compared to other scanning measurement methods like e.g. microplate readers. In addition to saving hands-on time with the one step Auto Sample Feature, you attain detailed information for each sample – including full high resolution scan results along with sample purity ratios.

The NanoPhotometer® N120 features our unique and proprietary 12 Point Technology™ which consists of several positioning guides for single and multi-channel pipettes. Patented illuminated sample windows and animated sample processing grid ensures convenient and error free sample application. The design is compatible with various multi-channel pipettes and supports the user while positioning the tips on the sample windows.

Implen NanoPotometer® N120 21 CFR Part 11 Compliance

Fully Compliant!

In March of 1997, the United States Federal Drug Administration (FDA) issued final Part 11 regulations that provide criteria for the acceptance of electronic records, electronic signatures, and handwritten signatures executed to electronic records by the FDA as equivalent to paper records and handwritten signatures executed on paper under certain conditions.

21 CFR Part 11 became effective in August 1997 and since then has been constantly revised and narrowed to minimize the efforts for the industry whilst protecting the public health efficiently.
After several optimizations steps, the FDA today is intending to enforce provisions related to the following controls and requirements:1

  • Limiting system access to authorized individuals
  • Use of operational system checks
  • Use of authority checks
  • Use of device checks
  • Determination that persons who develop, maintain, or use electronic systems have the education, training, and experience to perform their assigned tasks
  • Establishment of and adherence to written policies that hold individuals accountable for actions initiated under their electronic signatures
  • Appropriate controls over systems documentation
  • Controls for open systems corresponding to controls for closed systems bulleted above
  • Requirements related to electronic signatures

1 Part 11, Electronic Records; Electronic Signatures – Scope and Application

Ideal 21 CFR Tool for GLP/GMP/GxP Laboratories

The Implen NanoPhotometer® N120 CFR21 software complies with the current FDA 21 CFR Part 11 requirements and is an optional software tool ideal for GLP/GMP/GxP laboratories, which require proper electronic record keeping. Implen’s CFR21 software includes

  • User management
  • Access control
  • Electronic signatures
  • Data integrity
  • Data security
  • Audit trail functionality

For a detailed list of CFR21 software features and the corresponding FDA requirements please refer to the following information

 

CFR21 Software Statement    Compare to NanoDrop™

Installation and Operation Qualification (IQOQ)

implen nanophotometer 21 cfr part 11 compliance GLP lab
The NanoPhotometer® IQOQ package consists of a liquid standard and an Excel based software tool. The liquid standard is based on a non-toxic compound absorbing at 280 nm to cover the area of most interest for Life Science Applications. The liquid standard comes with a certificate of compliance. The Excel based software produces an automated report displaying all relevant data for an audit. The IQOQ procedure is fully described within the report documents and is simple and straightforward so that it can be carried out by a local lab technician to save time and cost.

 

Download Sample Report

LIMS Integration via REST API

implen nanophotometer spectrophometer N120 21 cfr part 11 compliance GLP lab

To add a variety of options and to increase efficiency to your workflow by integrating the NanoPhotometer® N120 with your LIMS to control processes, eliminate errors and save time.

The NanoPhotometer® N120 can be integrated with any LIMS software provider via our proprietary REST API allowing not only to obtain data from the instrument straight into the worksheet, but also to execute methods that have been established within LIMS. Please contact your local Implen support Team to learn more about the option and to get the integration process started.

Compare to NanoDrop™ 8000

The table below demonstrates a comparison of the spectrophotometers 8-channel NanoDrop™ 8000 vs. 12-channel NanoPhotometer® N120

Features NanoDrop™ 8000 Implen NanoPhotometer® N120
21 CFR Part 11 Upgrade
Software Control N/A Stand-Alone and/or control via Windows and Mac OS
User Management N/A Yes
Audit Trail  N/A Yes
Electronic Signature N/A Yes
Instrument Performance
Number of Samples Up to 8 Up to 12
Single sample mode available
Minimum Sample Volume 1 µL
2 µl sample size is recommended for protein measurements
2 – 3.5 μL
Pathlength 0.2 and 1 mm Utilizes two fixed path lengths 1 and 0.125 mm
Fixed path lengths never change over the lifetime of the instrument
Measurement Time Less than 20 seconds
220 – 750 seconds for 8 samples
20 seconds for 12 samples
(full scan 200 – 900 nm)
Enclosed Sample Measurement Surfaces NO

Column is exposed to surroundings

YES
Enclosed sample measurement surfaces
No evaporation
Accurate results independent from environmental conditions
Ability to measure proteins with detergent buffers without sample build-up
Analyze Organic Solvent Samples in a Drop N/A The NanoPhotometer® Sample Compression Technology allows the analysis of organic solvent samples in a drop and in a cuvette
Detection Range* dsDNA: 2.5 – 3,700 ng/µl
BSA: 0.15 – 100 mg/ml
dsDNA: 2 – 8,000 ng/µl
BSA: 0.06 – 230 mg/ml
Optical Specifications
Measurement Wavelength Full scan from 190 – 850 nm Full scan from 200 – 900 nm
Illuminated Read Head N/A Illuminated read head for an easy sample application
Light Source Xenon Flash Lamp Xenon Flash Lamp
Instrument Features
Quality Control Warnings N/A Sample Control™: quality control technology identifies sample impurities, potential contaminants, turbidity and lint residue
Blank Control™: prevents inaccurate readings caused by high background blanks or insufficient cleaning
Built-in Web Application Server N/A Full Web Application Server with REST API
Processing Power, Compatibility, Data Processing
Operating System N/A
Needs to be connected to a Windows computer
Linux based NPOS (NanoPhotometer Operating System)
Open platform to connect to Windows, Mac OS, Android, iOS via web application interface
Onboard Processor N/A Built-in computer with high-performance Intel Celeron dual core 2.4 GHz processor
Internal Data Storage N/A

128 GB for storage of thousands of measurements

Software Compatibility Compatible with Windows only Compatible with Windows 7, 8, 10 (32 and 64 bit), Mac OS X, iOS and Android OS
Data Transfer and Connectivity Options USB The unit includes 2x USB A, USB B, HDMI, Ethernet, WiFi
Data Output Separate as .csv .tsv .sql Complete data as PDF & Excel
Instrument Control The device must be connected to a computer via USB cable for operation, control and data storage. Easy control of the NanoPhotometer is possible via Wi-Fi from tablets or smartphones (Android OS & iOS). Control from PCs via LAN, WiFi or USB (Windows & Mac). The HDMI port allows for presentations directly from the device.
WiFi Hotspot N/A Built-in WiFi hotspot and with WiFi client capability
Instrument Dimensions 24 × 32 cm
(89.4 × 12.6 inches)
20 x 20 x 12 cm
(7.9 x 7.9 x 4.7 inches)

* dsDNA tends to precipitate/coagulate at concentrations above 10,000 ng/µl and should be diluted.

NanoDrop™ and NanoDrop™ One are registered trademarks of Thermo Fisher Scientific.
Implen® is not affiliated, sponsored or endorsed by Thermo Fisher Scientific or NanoDrop™.

Implen’s Overcoming 21 CFR Part 11 Limitations of Other Technologies

Have you experienced any of these difficulties finding the right technology?

  • No user management/21 CFR part 11 compliant software available
  • User management/21 CFR part 11 compliant software only available via external computer (no stand alone option)
  • No REST API interface available to connect to your LIMS System
  • Complex and pricy IQOQ procedures only offered with an expensive contract for onsite service
  • Long measurement times
  • Cumbersome software user interface
  • Costly recalibration/maintenance or decreasing accuracy over time
  • Instrument’s service and support discontinued and software not compatible with Windows10 or Mac OS
  • Low reproducibility (mainly caused by evaporation effects)
  • Getting results for more than 40 samples per run is time consuming
  • Waited for weeks to get instrument repaired
other-technologies-instruments-difficulties

How about trying a device that overcomes
all of these 21 CFR issues?

implen nanophotometers number one nanodrop alternatives N120 NP80 N60 C40

NanoPhotometer® Models    Request a Quote

Implen NanoPhotometer® N120 Reviews

Really impressed with the accuracy, ease of use, and increased sample throughput

Rating: 5.0   ★★★★★

Application Area: DNA Analysis

“I’ve really been impressed with the accuracy, ease of use, and increased sample throughput with this instrument. All this in such a small and sleek black box. The touch screen interface is a nice feature and very straightforward. You can easily navigate through the applications, load templates, access and analyze your data. I like that you’re given the option to run up to 12 samples at a time but you can also choose to run 1 or 2 samples, customizable to your experiments. Having options is always a plus and you get that with the N120. The pipette guide makes it really easy to apply your samples. I can see that a lot of time, expertise, and careful considerations went into developing the NanoPhotometer.”

Nam Che
Organization: UCLA Department of Medicine, USA

Very good for DNA quantification

Rating: 5.0   ★★★★★

Application Area: Research and development

“We bought N120 for quantifying a lot of DNA samples. I think this machine is best instrument.”

Dr. Masakazu Ishikawa
Organization: KOTAI Biotechnologies, Japan

#1 Alternatives from Implen

If you like to learn more about our technology and get an introduction into our range of cutting edge spectrophotometers and its advantages, please get in touch with one of our team or your local distribution partner.

Request a Quote

NanoDrop™ and NanoDrop™ One are registered trademarks of Thermo Fisher Scientific.
Implen® is not affiliated, sponsored or endorsed by Thermo Fisher Scientific or NanoDrop™.

Scroll to Top